Liquid Circulation Heat Exchanger 

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

Professional Design Kitchen Window Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures

Professional Design Kitchen Window Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Recent Air Regulations: Impact on Turnaround Vapor Deinventory Strategies | Air Heat Exchangers
Study Finds Dinosaurs Battled Overheating with Nasal Air-Conditioning | Whole House Air Exchanger

As a way to present you with ease and enlarge our enterprise, we also have inspectors in QC Workforce and assure you our greatest support and solution for Professional Design Kitchen Window Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: St. Petersburg, Kuala Lumpur, Adelaide, We are committed to meet all your needs and solve any technical problems you may encounter with your industrial components. Our exceptional products and vast knowledge of technology makes us the preferred choice for our customers.
commercial heat recovery ventilator
Single Room Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
Heat Recovery Ventilators
Ductless Heat Recovery Ventilator
Heat Recovery Ventilator

The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
5 Stars By Joanna from Kyrgyzstan - 2015.09.29 13:24
Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
5 Stars By Jean from St. Petersburg - 2016.05.31 13:26

Related Products