PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop

Short Description:


Product Detail

Tags

Feedback (2)

The key to our success is "Good Product Excellent, Reasonable Rate and Efficient Service" for Mechanical Heat Recovery System, Hrv Air, Tranter Heat Exchanger, "Making the Products of High Quality" is the eternal goal of our company. We make unremitting efforts to realize the goal of "We Will Always Keep in Pace with the Time".
PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures

PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Tesla Model 3 Cabin Air Filter Put To Real-World Test | Air Heat Exchangers
Comparing THT Heat Transfer Technology (OTCMKTS:THTI) and Paul Mueller (MUEL) | Silent Ventilation Fan

Our advancement depends over the highly developed devices, excellent talents and continually strengthened technology forces for PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Egypt, Borussia Dortmund, Cape Town, In order to carry out our goal of "customer first and mutual benefit" in the cooperation, we establish a specialist engineering team and a sales team to supply the best service to satisfy our customers' requirements. Welcome you to cooperate with us and join us. We have been your best choice.
commercial heat recovery ventilator
Single Room Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
Hrv Heat Recovery Ventilator
Heat Recovery Ventilator

Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
5 Stars By Atalanta from Danish - 2015.07.12 12:19
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
5 Stars By Victor from Latvia - 2016.01.28 19:59

Related Products