With reliable quality process, good reputation and perfect customer service, the series of products produced by our company are exported to many countries and regions for Fresh Air Fans, Air Handling Unit Manufacturers, Whole House Ventilation, "Change for that improved!" is our slogan, which means "A better globe is before us, so let's take pleasure in it!" Change for the better! Are you all set?
OEM Factory for Source Heating Air Conditioning - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger 

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

OEM Factory for Source Heating Air Conditioning - Liquid Circulation Heat Exchangers – Holtop detail pictures

OEM Factory for Source Heating Air Conditioning - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Cooperation
Are annual furnace inspections really necessary? | Air Heat Exchangers

The key to our success is "Good Product or service High quality, Reasonable Rate and Efficient Service" for OEM Factory for Source Heating Air Conditioning - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Lyon, Hongkong, Malaysia, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, thorough meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators

The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
5 Stars By Freda from Oslo - 2015.12.14 15:26
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
5 Stars By Karl from Buenos Aires - 2016.10.25 15:53

Related Products