Factory wholesale Window Fans 220v - Sensible Plate Heat Exchanger – Holtop
Factory wholesale Window Fans 220v - Sensible Plate Heat Exchanger – Holtop Detail:
in Features
- Sensible heat recovery
- Total separation of fresh air & exhaust air streams
- Heat recovery efficiency up to 80%
- 2-side press shaping
- Double folded edge
- Completely joint sealing.
- Resistance of pressure difference up to 2500Pa
- Under pressure of 700Pa, air leakage less than 0.6%
Material type
B series (standard type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Max. air temperature 100℃, it is suitable for most of the occasion.
F series ( Anti-corrosion type)
Heat exchanger is made of pure aluminum foils cover by special anti-corrosion material, with galvanized end cover and aluminium alloy wrap angle., it is suitable for the corrosive gas occasion.
G series (high temperature type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Sealing material is special and allow the Max. air temperature to be 200℃, it is suitable for special high temperature occasion.
Aluminum foils thickness range from 0.12 to 0.18mm because of the different specification heat exchanger.
Heat exchanger size and air volume
Remarks:① Length is customized, but should be within the specified range.
② Size C is for reference, size can be slightly increased according to heat exchanger length. |
Specifications
Model | A (mm) | B (mm) | C (mm) | Length per piece (L) | Optional spacing (mm) | Remarks |
HBS-ZF250/250 | 250 | 250 | 356 | <=400 | 4.0 |
One module |
HBS-ZF300/300 | 300 | 300 | 427 | <=400 | 4.0 | |
HBS-ZF300/300 | 300 | 300 | 427 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=400 | 4.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=550 | 6.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=400 | 4.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=500 | 5.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=550 | 6.0 | |
HBS-ZF500/500 | 500 | 500 | 710 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF600/600 | 600 | 600 | 851 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF700/700 | 700 | 700 | 993 | <=550 | 8.0, 10.0 | |
HBS-ZF800/800 | 800 | 800 | 1134 | <=550 | 8.0, 10.0 | |
HBS-ZF1000/1000 | 1000 | 1000 | 1417 | <=500 | 6.0, 8.0, 10.0 | Four modules combined |
HBS-ZF1200/1200 | 1200 | 1200 | 1702 | <=500 | 6.0, 8.0, 10.0 | |
HBS-ZF1400/1400 | 1400 | 1400 | 1985 | <=500 | 8.0, 10.0 | |
HBS-ZF1600/1600 | 1600 | 1600 | 2265 | <=500 | 8.0, 10.0 |
Product detail pictures:
Related Product Guide:
The howl and death of wolf 926F — High Country News | Whole House Air Exchanger
Why Do You Need Proper Air Ventilation System in Any Building?
Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction for Factory wholesale Window Fans 220v - Sensible Plate Heat Exchanger – Holtop, The product will supply to all over the world, such as: Sevilla, San Francisco, Marseille, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a should for you personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We are confident that we'll have a vibrant prospect and to be distributed all over the world in the years to come.
Ductless Heat Recovery Ventilator
Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
commercial heat recovery ventilator
By Christian from Lyon - 2015.09.29 17:23
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
By Arabela from luzern - 2015.05.13 17:00