Europe style for Central Air Conditioning Vents - Sensible Plate Heat Exchanger – Holtop
Europe style for Central Air Conditioning Vents - Sensible Plate Heat Exchanger – Holtop Detail:
in Features
- Sensible heat recovery
- Total separation of fresh air & exhaust air streams
- Heat recovery efficiency up to 80%
- 2-side press shaping
- Double folded edge
- Completely joint sealing.
- Resistance of pressure difference up to 2500Pa
- Under pressure of 700Pa, air leakage less than 0.6%
Material type
B series (standard type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Max. air temperature 100℃, it is suitable for most of the occasion.
F series ( Anti-corrosion type)
Heat exchanger is made of pure aluminum foils cover by special anti-corrosion material, with galvanized end cover and aluminium alloy wrap angle., it is suitable for the corrosive gas occasion.
G series (high temperature type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Sealing material is special and allow the Max. air temperature to be 200℃, it is suitable for special high temperature occasion.
Aluminum foils thickness range from 0.12 to 0.18mm because of the different specification heat exchanger.
Heat exchanger size and air volume
Remarks:① Length is customized, but should be within the specified range.
② Size C is for reference, size can be slightly increased according to heat exchanger length. |
Specifications
Model | A (mm) | B (mm) | C (mm) | Length per piece (L) | Optional spacing (mm) | Remarks |
HBS-ZF250/250 | 250 | 250 | 356 | <=400 | 4.0 |
One module |
HBS-ZF300/300 | 300 | 300 | 427 | <=400 | 4.0 | |
HBS-ZF300/300 | 300 | 300 | 427 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=400 | 4.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=550 | 6.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=400 | 4.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=500 | 5.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=550 | 6.0 | |
HBS-ZF500/500 | 500 | 500 | 710 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF600/600 | 600 | 600 | 851 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF700/700 | 700 | 700 | 993 | <=550 | 8.0, 10.0 | |
HBS-ZF800/800 | 800 | 800 | 1134 | <=550 | 8.0, 10.0 | |
HBS-ZF1000/1000 | 1000 | 1000 | 1417 | <=500 | 6.0, 8.0, 10.0 | Four modules combined |
HBS-ZF1200/1200 | 1200 | 1200 | 1702 | <=500 | 6.0, 8.0, 10.0 | |
HBS-ZF1400/1400 | 1400 | 1400 | 1985 | <=500 | 8.0, 10.0 | |
HBS-ZF1600/1600 | 1600 | 1600 | 2265 | <=500 | 8.0, 10.0 |
Product detail pictures:

Related Product Guide:
The howl and death of wolf 926F — High Country News | Whole House Air Exchanger
LHT develops automated steam cleaner for engine heat exchangers | Silent Ventilation Fan
Our enterprise since its inception, constantly regards product good quality as organization life, constantly improve production technology, strengthen merchandise high quality and continuously strengthen enterprise total good quality administration, in strict accordance with all the national standard ISO 9001:2000 for Europe style for Central Air Conditioning Vents - Sensible Plate Heat Exchanger – Holtop, The product will supply to all over the world, such as: Russia, Slovak Republic, India, The president and all the company members would like to provide professional products and services for customers and sincerely welcome and cooperate with all native and foreign customers for a bright future.
Hrv Heat Recovery Ventilator
Heat Recovery Ventilators
Ductless Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator

The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.